Structural Details​

The roof structure system employed in the Adult Learning Centre is exposed on the first floor, with rafter, beams and column connections visible. The 1:5 details provided show two of these features and their components. 

D

E

B

C

A

Column detail

Steel seat plate a

Flange bolt and nut b

CLT beam c

 Cap plate welded to UC d

Universal column (UC)e

A

B

C

D

E

Rafter/Beam connection

CLT timber beam a

Carriage bolt and nut b

CLT timber rafter c

 Flange bolt and nut d

Ridge rafter connector e

bottom of page